  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
15 •
PROBLEM REASON SOLUTION
Alarm is On Display shows . De-
vice demands too much
surge power.
or
Device has a short circuit
Display shows . 12-
volt battery is too low.
Display shows voltage
in between 10.5 and
11.0-volts.
Cycle the inverter power
OFF and ON. If problem
persists, use a larger
inverter or a smaller
device.
Remove the defective
device.
Recharge/replace
battery
12-volt battery is low.
Recharge or replace
battery. The inverter
will automatically shut
off after battery voltage
reaches 10.5-volts.
TROUBLESHOOTING10.