Schumacher MKC-10 User Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
5
BATTERY
POSITIVE
NEGATIVE
24", 6 GAUGE
CABLE
POWER
CORD
+-
BATTERY CHARGER
1. Check polarity of battery posts. Battery case will be marked
by each post: POSITIVE (POS, P, +) and NEGATIVE (NEG, N,
-). NOTE: The positive battery post usually has a larger diam-
eter than the negative post.
2. Attach a 24-inch long (or longer) 6-gauge (AWG) insulated
battery cable to NEGATIVE (NEG, N, -) battery post.
3. Connect POSITIVE (RED) charger clip to POSITIVE (POS, P,
+) post battery. Rock clip back and forth to make good con-
nection.
4. Position yourself and free end of 24 inch cable as far away
from battery as possible. Then connect NEGATIVE (BLACK)
charger clip to free end of cable. WARNING: Do not face
battery when making final connection. Rock clip back and forth
to make a good connection.
FIGURE 7 shows the connection.
5. Plug charger AC cord into 120 volt grounded outlet.
6. Turn switch from off to on.
7. When battery is fully charged, unplug charger from AC
power source.
8. When battery is fully charged and charger is unplugged, (1)
remove clip from end of Negative end of cable, and (2)
remove clip from Positive battery post, in that order.
9. Clean and store battery charger.
FIGURE 7 CONNECT NEGATIVE BATTERY CLIP
TO 24 INCH CABLE END
TO GROUNDED
POWER OUTLET